Skip to content
VETCNCCNC MANUFACTURING
Silver multi-port manifold body beside a smaller ivory flow block

Custom manifold blocks for fluid routing and valve interfaces

Manifold Blocks, Subplates and Ported Bodies

Cross-drilled distribution blocks

We machine a main gallery with intersecting branches and the access holes used to make them. The body routes fluid between the ports shown on your drawing.

Valve subplates

A machined mounting face connects a surface-mounted valve to the block’s supply, return and working passages. The interface includes the face ports and fastening pattern.

Cartridge-cavity blocks

Stepped cavities receive the selected screw-in cartridge. We machine the block to its specified cavity drawing, including the internal shoulders and separate passage entries.

Threaded junction blocks

Compact bodies connect passages approaching from several directions. Each connection carries its own port designation so an inch, metric or pipe-thread interface remains identifiable.

Distribution bars

An elongated gallery supplies a row of branch outlets. Outlet pitch, mounting points and end connections define how the bar fits beside the equipment it serves.

Multi-face port adapters

Adapter bodies place different connection interfaces on the required faces. The internal route joins the selected ports without needing the outside fittings to share an axis.

Covered-channel bodies

An open milled channel gives access to a route that cannot be drilled as a straight gallery. We supply the drawing-defined body and, where included, its separate cover; joining and assembly have their own scope.

Polymer flow blocks

We machine ported bodies in the specified engineering plastic. These parts suit designs that select a polymer wetted path rather than using a metal block interchangeably.

8 block types shownWe machine these component forms to the released design. Valves, fittings, seals and assembly are included only when identified in the quotation.

Materials for Custom Manifold Blocks

Dark metal block with a concentric stepped threaded cavity and two side ports

Steel, stainless steel and brass

Stainless steel is an option when the design specifies a corrosion-resistant metallic wetted path. Steel and brass remain distinct selections for the block and its threaded interfaces; these metals are heavier than aluminum at the same geometry. The named grade and condition govern the supplied material.

Ivory flow block with three top openings, two threaded side ports and one larger end bore

Engineering polymer blocks

We machine POM, PEEK and other specified engineering plastics for flow-distribution bodies. Fluid exposure, temperature and sustained fitting loads affect the selection. The port’s wall section and connection design need to suit the chosen polymer.

Valve Faces, Port Seals and Passage Alignment

Silver valve subplate with four top fluid openings, four fixing holes and two side ports

Valve mounting interface

The valve-side ports and fixing holes must share the mounting face’s datum system. The seals land over the intended openings because the ports and fixing holes share the mounting face's datum system. Locating features also establish the required valve orientation.

Sections comparing a straight-thread port entrance with tapered thread walls

Complete port and seal geometry

A straight-thread O-ring port uses more than its tapped hole: the lead-in, seal housing and surrounding face are part of the connection. A thread gauge checks the thread; the seat and entry geometry still need their own dimensional acceptance.

Section of intersecting straight passages with common axes and a separate access closure

Passages between different faces

Drill axes and depths determine which galleries meet inside the body. A passage that stops short leaves an unintended restriction; one that goes too far can open into another circuit. We use the drawing’s common datums and depth definitions for these cross-face relationships.

Port and Internal Feature References

Manifold interface and internal-feature references
FeatureReference or drawing calloutAcceptance focus
Inch SAE O-ring boss port-4: 7/16–20; -6: 9/16–18Selected thread plus complete O-ring port geometry
Metric ISO 6149 portM12×1.5 or M14×1.5Metric thread and specified seal housing
NPT pipe-thread port1/4–18 NPT; 1:16 diameter taperTapered thread engagement and specified sealing method
Cartridge cavitySelected cavity identifier and drawing revisionShoulders, seal leads and passage entry locations
Face-mounted valve interfaceSpecified mounting designation and face requirementsPort pattern, locating features and sealing land
Cross-gallery and closureSpecified bore axes, depths and closure positionRequired intersections and remaining circuit separation

Selected interface references from Parker port guides; the full port standard and fitting drawing govern sealing geometry and acceptance. Unified callouts give diameter in inches and threads per inch; metric pitch is in millimetres. The NPT fraction is a nominal pipe size. The references describe the published port standards; the tolerances and pressure rating for your block come from its released drawing.

Machining the Internal Flow Paths

Three stages showing drill access, internal intersection edges and access closure
Cross-drilled passages and accessible cavity features

Straight galleries and drill access

A drilled gallery follows a straight tool path. Its entry face, depth and intersection with the next bore have to be reachable in the planned setup. A closed curved route needs a different component construction, such as the covered-channel form shown above.

Stepped cartridge cavities

Cartridge cavities combine several diameters, shoulders and seal-entry features. The finishing tool follows the selected cavity profile and locating shoulder. Sun Hydraulics’ cavity guidance also warns that reaming cannot be expected to correct a drilled hole that has wandered off its intended axis.

Internal intersections and closure access

Burrs at crossing bores can remain inside an otherwise finished block. The route needs access to remove them and clear the passages before closures hide the intersections. A difficult internal edge must be resolved in the machining plan rather than treated as an outside chamfer.[3]

Finished Surfaces, Closure Seats and Port Marking

Sealing lands and working faces

The selected seal interface sets the surface-finish requirement. Keeping a sealing land free of a scratch or edge defect is different from specifying an attractive exterior texture; their acceptance areas remain separate on the part.

Coating coverage

External coating and internal treatment are different specifications. Coverage, masking and process access affect whether the specified layer reaches a passage or changes a port’s final dimensions. We quote the required finish areas and final condition.

Closure installation surfaces

An expansion-plug bore or threaded closure seat follows the selected closure design. Its accepted diameter and surface condition apply at installation; coating that changes the seating zone cannot be added without accounting for that change.

Port identification

Markings connect each physical port to the released circuit map. They must remain legible after finishing without damaging a seal zone.

Finish and marking operations must not leave loose residue inside the fluid paths. [3]

Inspection of the Machined Manifold Body

Ports, valve faces and cavities

Our dimensional scope follows the specified port, mounting-face and cavity features. Sizes, depths and datum relationships are checked against the released drawing in the quoted final condition.

Connected and isolated passages

Acceptance must distinguish an intended open connection from an unintended connection between circuits. The port map identifies both. Any required passage verification, cleanliness acceptance or pressure-related testing is defined separately from the dimensional report in the quotation.

Block and configuration identity

Part number, revision and batch identity connect the supplied body to its material, finish and agreed inspection records.

Port entrance, datum-related hole pattern and internal-edge inspection diagrams
Feature acceptance follows the specified port and cavity design

From First Manifold Body to Repeat Orders

First installation check

A first body allows your assembly review to establish fitting access, valve clearance and the installed port orientation before release of the repeat component.

Freeze the accepted circuit

The accepted configuration includes hidden galleries, closure positions and valve interfaces. An unchanged exterior model does not authorize a change inside the block.

Keep variants distinct

A different port map needs a controlled part or revision identity. Marking and packing keep similar-looking blocks from being mixed at installation.

Protect open connections

Packing protects sealing faces and port entries and keeps loose material out of open passages. Temporary shipping protection remains distinguishable from a specified circuit closure.

What changes machining cost?

The number of machining faces, deep galleries, cartridge cavities and inaccessible intersections drives setup and tooling work. A larger repeat quantity spreads programming and fixture preparation over more bodies; it does not remove the per-part work of making and finishing the internal features.

Sample and Production Orders

Information for a Manifold Block Quote

Component package and internal circuit definition
IncludeRequired detail
Body model and circuit mapPassage sections, port labels and intended connected or isolated networks
Connection and valve interfacesPort standards, fitting drawings, valve pattern and cavity identifiers/revisions
Closure and finished conditionPlug/closure part references and depths; finish areas, masking and supplied assembly state
Order and acceptanceMatching part/revision, material/condition, quantity, records and separately specified tests

Use a controlled drawing or section view for hidden features that a simplified solid model does not fully define. Agree secure file transfer for restricted designs.

Custom Manifold Block FAQs

Does a 6061 aluminum block have a standard working-pressure rating?

No. Safe working pressure comes out of the pressure design for that block. Wall sections, intersecting bores, closures, temperature and the selected connections all affect the design. ISO 6149-1 also makes permissible connection pressure dependent on size, material, design and application. We quote the machined component against the released design rather than assigning a stock pressure rating to every aluminum block.

Does an ISO 4401 valve mounting pattern define the manifold circuit?

No. ISO 4401 defines mounting-surface dimensions for four-port directional valves so the interfaces can be interchangeable. It does not choose which passages connect inside your body or which valve function your system needs. The selected mounting designation and the separate internal circuit definition are both needed.

Are cartridge cavities interchangeable when their threads match?

Not necessarily. The thread is only one feature. Shoulder depths, sealing diameters, lead-ins and the locations at which passages enter the cavity can differ. Use the selected cartridge manufacturer's cavity identifier and controlled drawing, since the shoulder depths, sealing diameters and lead-ins are what make the valve seat and operate correctly.

Should a cross-drill closure be permanent or removable?

That depends on whether the opening is a manufacturing access hole or a future service point. A permanent expansion plug seals by expanding into its prepared housing; it is not interchangeable with a removable threaded closure. A removable design preserves maintenance access but needs its own sealing and retention geometry. The chosen closure defines the machined seat and its installation requirements.

Can the nominal port size establish the manifold’s flow capacity?

No. A port label does not describe the smallest internal passage, the path length, turns or installed restrictions. Flow must be considered with the fluid condition and the permitted pressure drop through the complete route. The machining drawing defines the geometry we supply; it does not by itself create a tested flow rating.

Can one block carry two independent fluids or circuits?

A design can contain isolated passage networks, but their separation must be explicit. Crossing drill paths, plug depths and any shared interface need to preserve that isolation. If cross-circuit leakage is an acceptance concern, the component specification must identify that requirement separately from leakage to the outside. The block’s exterior dimensions cannot demonstrate isolation.

PROJECT SUPPORT

Discuss Your Custom Manifold Block

Send the released body drawing, port map and interface references with the material and quantity. We will quote the machined component and identify the included finish, records and delivery condition.

Technical References

Interface definitions and manufacturing references used on this page.

  1. Parker — Port and pipe connection reference tables — Catalog 4300 and associated fitting guides: selected SAE, ISO 6149 and NPT thread examples. NIST pipe-thread reference and Webtec connection guidance support the NPT diameter taper.
  2. Sun Hydraulics — Cavity Machining Notes — Stepped cavity geometry, locating shoulders and drill/reamer relationships.
  3. Sun Hydraulics — Hydraulic System Cleanliness, January 2022 — Internal intersections, burr removal, marking residue and passage protection.
  4. The Lee Company — Lee Plug technical and installation guidance — Permanent expansion closures, installation-hole requirements and separately removable closure designs.
  5. ISO 6149-1:2022 and ISO 4401:2005 — Metric O-ring port definitions and the mounting-surface scope of four-port directional valves.
VETCNCCNC MANUFACTURING

Get a Quote

Upload Drawing

*Required fields

Part example

English
WhatsApp Email us

Tell us about your project

Share your requirements and we will get back to you by email.

PDF, CAD or ZIP · up to 20 MB