Skip to content
VETCNCCNC MANUFACTURING
Silver metal adapter with a hexagonal wrench body, external thread and open bore

Custom Machined Sensor Fittings

Probe Adapters, Process Fittings and Mounting Hardware

Threaded probe-adapter bodies

A through bore receives the specified probe or sleeve while an external connection mounts the body. We machine the bore, retaining thread and adjacent shoulder as related features so the fitting positions the probe from the intended interface.

Through-bore mounting bushes

A bush guides a cylindrical probe through a panel or support. Its bore and seating shoulder establish the mounting position; it does not become a pressure-sealing assembly simply because the probe fits through it.

Reducing process adapters

Different inner and outer connections allow a selected instrument to meet an existing port. We preserve both connection definitions and the internal clearance between them, including the seat or sealing region at each end.

Union bodies and retaining nuts

A separate nut retains the fitting against its released mating body. We supply the identified body or nut with its thread, bearing face and required tool access; the parts included in the order remain explicit.

Flanged sensor mounts

A flange locates the probe bore from a mounting face and fastening pattern. Its register, gasket boundary and attachment details follow the selected interface rather than an assumed universal flange connection.

Offset and angled fitting bodies

An offset body places the probe connection away from the process-side axis or at a released angle. The intersecting passage, end position and surrounding installation clearance are defined with the two interfaces.

Insert and seal carriers

A separate carrier supports the specified insert or seal within the fitting. We machine its locating diameter, shoulder and entry edge so the retained part occupies the released position without substituting a generic groove.

Mounting collars and axial spacers

Collars and spacers set the position of a probe holder or surrounding support. Their accepted lengths and contact faces control the installed stack; clearance and split or fastening details follow the actual drawing.

8 component formsWe supply drawing-defined sensor fitting components and mounting hardware, with the ordered material, surface condition and dimensional inspection. Sensors, ferrules, seals and mating hardware are included only when named in the quotation. Sensor electronics, complete pressure-assembly approval and hygienic-system qualification remain separate from machining the fitting.

Wetted Fitting Materials and Dry-Side Mounts

Golden metal adapter with two threaded ends and an open passage

Brass adapter components

Brass can be specified for threaded adapter bodies, nuts and mounting details. Its actual grade and any plating remain part of the supplied condition, while the project determines whether the alloy is acceptable at the wetted interface.

White polymer through-adapter with a hexagonal body and internal and external threads

Aluminum and polymer mounting details

A dry-side collar, spacer or panel mount can use a different material from the process fitting. The design still accounts for the retained probe, tightening load and temperature; an external mounting material is not automatically an acceptable wetted substitute.

Relate the Probe, Seal and Process Connection

Fitting section distinguishing an external threaded region from the adjacent sealing reference

Define the thread and its actual seating geometry

A process connection includes the released thread and the surface that forms its seal. The WIKA references below illustrate how instruments with the same broad nominal thread family can retain different axial and seating geometry. The machined part follows the complete connection drawing.

Probe-bore axis related to an installed mounting face

Position the probe from the installed reference

The probe bore, retaining shoulder and process-side face establish where the sensing region sits after installation. We relate these features to the specified datum instead of using the fitting’s outside length as a substitute for the installed position.

Hexagonal fitting body with a surrounding tool-clearance outline

Retain access beside the fitted instrument

Hex flats, union-nut clearance and nearby side ports must remain accessible in the installed arrangement. A fitting that matches both thread callouts can still place its tool contact or surrounding body where the selected instrument cannot be fitted.

Process-Connection Dimensions Need Their Named Drawing

Selected WIKA pressure-instrument process-connection drawings
Named connection drawingPublished dimensionsInterface meaning
DIN EN ISO 1179-2, G ½ AL1 14 mm; L2 3 mmUse its stated sealing-face arrangement
EN 837, G ½ BL1 20 mm; L2 3 mmSeparate drawing from the G ½ A form
DIN EN ISO 9974-2, M14 × 1.5L1 12 mm; L2 2 mmRetain its metric connection geometry
ISO 6149-2, M14 × 1.5L1 11 mmSame thread label does not define the full seat
ANSI/ASME B1.20.1, ¼ NPTWIKA drawing L1 13 mmInstrument drawing dimension; not engagement turns
ANSI/ASME B1.20.1, ½ NPTWIKA drawing L1 19 mmRetain the selected port and installation definition

Source: WIKA IN 00.14, December 2025, pp.5–6. L1 and L2 retain the labels and scope of those pressure-instrument drawings, not universal thread-engagement lengths. The selected complete connection drawing defines the actual fitting.

Machine the Bore, Thread and Seating References

Open fitting bore beside a threaded stem and wrench flats
An open fitting bore and its adjacent thread shoulder

Turn the bore and related shoulders

We establish the specified probe bore, outside register and shoulder relationship through the fitting’s reference setup. A thin retaining section needs support through finishing so the released fit is not based on its clamped shape.

Complete the selected thread and sealing regions

The thread is made to its named definition while the seal land, entry relief and adjacent face retain their own dimensions. These features are inspected in the ordered final condition; a correct thread alone does not release an incorrect seat.

Add flats, angles and intersecting access

Milled flats and side connections follow the established fitting axis or mounting datums. Passage intersections are deburred with access to the internal edges, while the tool-contact region remains distinct from the probe’s locating surface.[1]

Protect the Probe Bore and the Working Seal Region

Keep entries free of damaging edges

Probe-bore entries and seal leads receive their specified edge condition. Removing a loose burr must not enlarge the guiding section or consume the shoulder that positions the insert.

Keep coating coverage explicit

Where plating or another finish is ordered, the drawing identifies threaded, seating and exposed regions. The accepted dimensions apply to that finished condition, including any masked bore or seal land.

Retain process-side cleanliness requirements

Record the required delivery cleanliness. If a particle or residue limit is specified, the order also defines how it will be verified.

Separate and protect finished contacts

Packing keeps seal faces, probe bores and threads from contacting other components. Any temporary shipping protection is distinguishable from a permanent plug or included assembly part.

Finished fitting surfaces are protected through packing; the order identifies any included seals, protective caps or mating hardware.

Inspect the Fitting’s Actual Mounting Interfaces

Thread and connection features

We check the named thread definition and its specified acceptance. The adjacent seat, shoulder, lead-in or sealing diameter remains a separate feature in the dimensional report.[2]

Bore, face and installed position

The probe bore, mounting face, register and axial dimensions are checked from the released datums. An offset fitting also retains its specified angle and relative port position.

Final component and assembly requirements

Material, finish and component identity remain associated with the inspection record. Any required leak, pressure, electrical or hygienic acceptance needs its separately agreed method, assembly state and responsibility; it is not inferred from dimensional results.

Fitting bore axis and axial references with a separate threaded end
Probe axis, seating face and connection geometry have separate checks

First Fittings, Accepted Interfaces and Repeat Supply

Establish the actual mating definition

The first component follows the controlled sensor, probe-holder and process-port interfaces. A sample may help identify an arrangement, but worn sealing or retaining surfaces are not silently copied as nominal geometry.

Evaluate installation with the intended parts

Initial fittings allow the project to check probe location, tool access and surrounding clearance with the selected instrument and mounting point. Any change to an interface becomes a released drawing revision.

Keep finishing and dimensional acceptance aligned

Repeat manufacture retains the accepted treatment, masked areas and final inspection state. A plated or otherwise processed fitting is not released solely from measurements taken before that operation.

Keep similar connections identifiable

Part and revision identity distinguish fittings that look alike but have different internal threads, seats or axial lengths. Packing and records preserve that identity through assembly.

Cost follows interfaces and access

Programming and holding preparation are spread over quantity. Two different thread systems, deep small bores, angled ports, thin retained sections and extra finished-state inspection still add work to each fitting; its small outside size does not remove those operations.

Discuss Samples and Production

Sensor Fitting Drawing and Supply Details

Definition of the supplied sensor fitting component
IncludeRelevant detail
Mating interfacesProbe or holder drawing, process connection, seat and included hardware
Position and accessBore and axial references, installation angle and tool clearance
Final material and acceptanceGrade/condition, finish regions, dimensional limits and separately defined tests
Supply identityPart/revision, variants, quantities, included seals, ferrules or caps

Agree a secure transfer method for confidential files.

Custom Sensor Fitting FAQs

Is a 12 mm process sensor’s A-length its overall length?

No. Hamilton measures the A-length of its traditional 12 mm sensors from the base of the PG13.5 mounting threads to the electrode tip. For its refillable sensors, the reference is the base of the refillable chamber. The selected holder has to suit that A-length, since insertion position is measured from the stated reference.

Does a G 1¼ Ingold retaining thread establish a flush process connection?

No. Hamilton’s holder guidance also relates the O-ring position on the body to the length of the mating socket. That relationship establishes the seal at the inner vessel wall and avoids an unintended dead space. The retaining thread designation alone does not release the required socket and seal-position combination.

Can BSPT and NPT be substituted because both threads are tapered?

No. Parker’s thread-identification guide gives a 55° profile for BSPT and a 60° profile for NPT and explicitly states that BSPT will not substitute for NPT. The fitting must retain the specified complete thread system, even if two parts begin to screw together.

Does an industrial bolted flange make a sensor mount a sanitary connection?

Not by itself. Hamilton distinguishes its ANSI/DN industrial flanges from its sanitary process connections. A flush, cleanable arrangement follows from the hygienic connection specified for the installation. The actual connection and installation specification govern that choice.

Can a compression body for a 12 mm stem accept a ½ inch stem?

The selected compression interface must match the actual tube or stem diameter. Half an inch is 12.7 mm, so it is not the same diameter as 12 mm. Hamilton’s connection guidance makes tube size part of the ferrule-fitting match; tightening a different stem into the body is not an approved dimensional substitution.

Can the sensor case be used to tighten the process fitting?

Use the installation tool contact defined by the instrument manufacturer. WIKA’s process-connection guidance requires the spanner flats at the thread and says the case must not carry that mounting load. The fitting drawing and installed access should preserve the intended wrench contact rather than require force through the instrument case.

PROJECT SUPPORT

Discuss Your Custom Sensor Fitting

Send the fitting drawing and the relevant probe, holder and process-port interfaces, with material, final condition and quantity. We will quote the included component machining, finishing and inspection.

Technical references and scope

Original process-connection drawings, thread definitions and probe-position references used on this page.

  1. WIKA — Information on Process Connections, IN 00.14, December 2025— Named pressure-instrument connection drawings, L1/L2 dimensions, seating variants and installation tool contacts.
  2. Parker — Instrument Tube Fitting Installation Manual, Bulletin 4200-B4, January 2023— NPT, BSPT and BSPP thread identification and distinct sealing arrangements, printed pp.62–64.
  3. Hamilton — What Type of Process Connection Does My Sensor Have?— Process-side connection families and their distinction from the electrical interface.
  4. Hamilton — How to Measure Sensor A-length— Manufacturer-specific measurement origins for traditional and refillable process sensors.
  5. Hamilton — Process Connection Options for Housings— Ingold seal/socket relationship, tube-size matching and sanitary versus industrial flange interfaces.
VETCNCCNC MANUFACTURING

Get a Quote

Upload Drawing

*Required fields

Part example

English
WhatsApp Email us

Tell us about your project

Share your requirements and we will get back to you by email.

PDF, CAD or ZIP · up to 20 MB